The RosEcoMat Roof Antifire insulation

RosEcoMat Roof Anti-fire is a material with increased resistance to fire, impregnated with fire-retardants* and consisting of linen (85%) and polyester fibers (15%).

12.79

Quantity Price Discount
400-1000 12.15 5%
1001+ 11.51 10%
Additional information
Body density, kg/m3

32

Thermal conductivity, W/mK

0.036

Specific heat capacity, J/kg K

1600-1650

Sound-absorption factor

LMH-211

Vapor permeability coefficient

0 , 37-0 , 41

Ultimate compressive strength, KPa

4-5

Описание

The plates have good vapor permeability, which creates the basis for a good indoor microclimate: excess moisture is removed, and warmth in winter and coolness in summer are preserved. The use of flax avoids the appearance of mold and other fungi. RosEcoMat Roofing plates are easy to install, do not require the use of special equipment. The use of such insulation guarantees high-quality insulation of the mansard roof with a long service life. Linen insulation for a residential roof is absolutely the right choice, which friends and acquaintances will approve. The linen roof will allow you to have a modern house in which there will always be comfort and coziness. *The anti-fire is fireproof. The insulation in the form of a plate withstands the effects of medium-intensity fire, does not spread flames (flammability rating – low-flammable and frugally-flammable). Fire protection is achieved by adding sea salt, which is not only an antiseptic, but also a fire-retardant. Because of their natural origin, linen slabs are not and cannot be absolutely non-combustible material (incombustible class). With an intense mass fire, when everything around will burn, any insulation will burn. In order for a person to have time to leave the room and not suffocate from harmful secretions, a line of Anti-fire insulation has been developed: the fire-retardant, which is part of RosEcoMat Roof Anti-fire copes with the task. The combustibility can be reduced due to some other additional impregnations, but we do not do this so as not to reduce the environmental friendliness of the material. The treatment of the plates with fire-retardants is superficial and in order to preserve the self-extinguishing effect, it is categorically not allowed to cut or otherwise violate the integrity of the plate. If this has happened, then it is necessary to cover the cut or break line with fire protection, for example, Senezh. If the cut line is not treated, then at that location, when an open flame appears, it is possible to ignite the entire mass of the plate, including other entire surfaces inside. *It is not allowed to place thermal insulation boards near an open fire, heating surface (fuel boiler, chimney).

Size and packaging

Length(mm) Width (mm) Thickness (mm) Package area(m2) Volume density(m3) Slabs in package
1000 600 30 9,6 0,288 16
1000 600 40 7,2 0,288 12
1000 600 50 6 0,3 10
1000 600 60 4,8 0,288 8
1000 600 80 3,6 0,288 6
1000 600 100 3 0,3 5
1000 600 120 2,4 0,288 4
1000 600 140 2,4 0,336 4
1000 600 160 1,8 0,288 3
1000 600 180 1,8 0,324 3
1000 600 200 1,2 0,24 2